Seite 1 - INSTALLATION INSTRUCTIONS

WALL MOUNTEDPACKAGE HEAT PUMPModelsWH184WH242INSTALLATION INSTRUCTIONSManual : 2100-423ASupersedes: 2100-423File: Volume III Tab 17Date: 09-01-03Bard

Seite 2 - Contents

Manual 2100-423Page 8FIGURE 5WALL MOUNTING INSTRUCTIONSSEE UNIT DIMENSIONS, FIGURE 1, FOR ACTUAL DIMENSIONSMIS-548MIS-549FIGURE 4WALL MOU

Seite 3 - Page 1

Manual 2100-423Page 9FIGURE 6COMMON WALL MOUNTING INSTALLATIONSMIS-550

Seite 4 - SHIPPING DAMAGE

Manual 2100-423Page 10WIRING – MAIN POWERRefer to the unit rating plate for wire sizing informationand maximum fuse or “HACR” type circuit

Seite 5 - UNIT DIMENSIONS

Manual 2100-423Page 11MIS-409FIGURE 8 – COMPRESSOR CUTOFF THERMOSTAT WIRING4 & 8 KW 1 Phase – 6 KW 3 PhaseWIRING – LOW VOLTAGE WI

Seite 6 - DUCT WORK

Manual 2100-423Page 12ELECTRIC HEAT HOLD-OFF ( See Figure 9)In other applications, it is desirable to disable theoperation of the electric h

Seite 7 - CAUTION

Manual 2100-423Page 13HEAT ANTICIPATIONGroup A and Group B thermostats shown in Table 4have a fixed heat anticipator for stage 1 with noadju

Seite 8 - INSTALLATION INSTRUCTIONS

Manual 2100-423Page 14START UPIMPORTANT INSTALLER NOTEFor improved start up performance, wash the indoorcoil with a dish detergent.CRANKCASE

Seite 9 - MOUNTING INSTRUCTIONS

Manual 2100-423Page 15PRESSURE SERVICE PORTSHigh and low pressure service ports are installed on allunits so that the system operating press

Seite 10 - FIGURE 4

Manual 2100-423Page 16TROUBLESHOOTINGSOLID STATE HEAT PUMP CONTROLTROUBLESHOOTING PROCEDURE1. Turn on AC power supply to indoor and outdooru

Seite 11 - FIGURE 6

Manual 2100-423Page 17 F R F R F R-25.0-24.0-23.0-22.0-21.0-20.0-19.0-18.0-17.0-16.0-15.0-14.0-13

Seite 12 - WIRING – MAIN POWER

ContentsGetting Other Informations and Publications 1Wall Mount General InformationHeat Pump Wall Mount Model Nomenclature... 2Shipping Damage

Seite 13 - WIRING – LOW VOLTAGE WIRING

Manual 2100-423Page 18FAN BLADE SETTING DIMENSIONSShown in Figure 12 are the correct fan blade settingdimensions for proper air delivery acr

Seite 14 - MIS-1858

Manual 2100-423Page 19Low Side Pressure ± 2 PSIGHigh Side Pressure ± 5 PSIGTables are based upon rated CFM (airflow) across the evaporat

Seite 15 - COMPRESSOR MALFUNCTION LIGHT

Manual 2100-423Page 20LEDOMNOITPIRCSED40A-A20HWHE80A-A20AWHE60B-41HWHE60C-B42HWHEsegakcaPretaeHsegakcaPretaeHsegakcaPretaeHsegakcaPretaeHXXX

Seite 16 - START UP

Manual 2100-423Page 1Getting Other Information and PublicationsThese publications can help you install the airconditioner or heat pump. You

Seite 17 - DEFROST CYCLE

Manual 2100-423Page 2WALL MOUNT GENERAL INFORMATION HEAT PUMP WALL MOUNT MODEL NOMENCLATURE NOTE: For 0 KW and circuit breakers (230/

Seite 18 - TROUBLESHOOTING

Manual 2100-423Page 3FIGURE 1UNIT DIMENSIONSMIS-992

Seite 19 - OUTSIDE UNIT CIRCUIT

Manual 2100-423Page 4Size of unit for a proposed installation should be basedon heat loss calculation made according to methods ofAir Condit

Seite 20 - REFRIGERANT CHARGE

Manual 2100-423Page 5MIS-938FIGURE 2FRESH AIR DAMPER ASSEMBLYAny grille that meets the 5/8 inch louver criteria may beused. It is recommen

Seite 21 - TABLE 12 – PRESSURE TABLE

Manual 2100-423Page 6INSTALLATION INSTRUCTIONSWALL MOUNTING INFORMATION1. These units are secured by wall mounting bracketswhich secure the

Seite 22 - OPTIONAL ACCESSORIES

Manual 2100-423Page 7FIGURE 3MOUNTING INSTRUCTIONSMIS-353